# Environmental Monitoring Standards Reference
|
|
|
|
This document provides the industry-standard optimal ranges used by the GPT service for environmental analysis.
|
|
|
|
## Supported Metrics
|
|
|
|
### Temperature (°C)
|
|
- **Optimal Range**: 18-24°C
|
|
- **Comfort Zone**: 20-22°C
|
|
- **Critical Low**: <15°C
|
|
- **Critical High**: >28°C
|
|
- **Standards**: ASHRAE 55, ISO 7730
|
|
- **Key Concerns**:
|
|
- Worker comfort and productivity
|
|
- Equipment operating conditions
|
|
- Energy efficiency
|
|
- HVAC system performance
|
|
|
|
### Humidity (%)
|
|
- **Optimal Range**: 30-60%
|
|
- **Comfort Zone**: 40-50%
|
|
- **Critical Low**: <20%
|
|
- **Critical High**: >70%
|
|
- **Standards**: ASHRAE 55, WHO guidelines
|
|
- **Key Concerns**:
|
|
- Mold and mildew growth (>60%)
|
|
- Static electricity and equipment damage (<30%)
|
|
- Respiratory health and comfort
|
|
- Material degradation
|
|
|
|
### CO2 (ppm)
|
|
- **Optimal Range**: 400-1000ppm
|
|
- **Comfort Zone**: 400-800ppm
|
|
- **Critical Low**: <350ppm (unusual indoors)
|
|
- **Critical High**: >1500ppm
|
|
- **Standards**: ASHRAE 62.1, WHO Air Quality Guidelines
|
|
- **Key Concerns**:
|
|
- Air quality and ventilation effectiveness
|
|
- Cognitive performance (>1000ppm affects decision-making)
|
|
- Occupant health and alertness
|
|
- HVAC system efficiency
|
|
- **Impact**: Studies show 15% decline in cognitive function at 1400ppm
|
|
|
|
### Atmospheric Pressure (hPa)
|
|
- **Optimal Range**: 1013-1023hPa
|
|
- **Comfort Zone**: 1013-1020hPa
|
|
- **Critical Low**: <980hPa
|
|
- **Critical High**: >1050hPa
|
|
- **Key Concerns**:
|
|
- Weather changes and ventilation
|
|
- Building pressurization
|
|
- Equipment calibration
|
|
- Occupant comfort
|
|
|
|
### Light / Illuminance (lux)
|
|
- **Optimal Range**: 300-500 lux
|
|
- **Comfort Zone**: 400-500 lux
|
|
- **Critical Low**: <200 lux
|
|
- **Critical High**: >1000 lux
|
|
- **Standards**: EN 12464-1, IESNA recommendations
|
|
- **Key Concerns**:
|
|
- Visual comfort and eye strain
|
|
- Productivity and task performance
|
|
- Energy consumption
|
|
- Circadian rhythm regulation
|
|
- **Note**: Higher levels (750-1000 lux) for detailed work
|
|
|
|
### Noise (dB)
|
|
- **Optimal Range**: 30-50dB
|
|
- **Comfort Zone**: 35-45dB
|
|
- **Critical Low**: <20dB (unusual indoors)
|
|
- **Critical High**: >70dB
|
|
- **Standards**: WHO Noise Guidelines, OSHA
|
|
- **Key Concerns**:
|
|
- Acoustic comfort and concentration
|
|
- Speech intelligibility
|
|
- Stress and productivity impact
|
|
- Hearing protection requirements (>85dB)
|
|
- **Impact**: 40-45dB ideal for office work, <35dB for focused tasks
|
|
|
|
### PM2.5 - Fine Particulate Matter (µg/m³)
|
|
- **Optimal Range**: 0-12 µg/m³
|
|
- **Comfort Zone**: 0-10 µg/m³
|
|
- **Critical Low**: 0 µg/m³ (best)
|
|
- **Critical High**: >35 µg/m³
|
|
- **Standards**: EPA Air Quality Index, WHO guidelines
|
|
- **Key Concerns**:
|
|
- Air quality and health risk
|
|
- Respiratory system impact
|
|
- Filter maintenance requirements
|
|
- Outdoor air quality correlation
|
|
- **Impact**: >35 µg/m³ = Unhealthy for sensitive groups
|
|
|
|
### VOC - Volatile Organic Compounds (ppb)
|
|
- **Optimal Range**: 0-220ppb
|
|
- **Comfort Zone**: 0-150ppb
|
|
- **Critical Low**: 0ppb (best)
|
|
- **Critical High**: >500ppb
|
|
- **Standards**: Various indoor air quality standards
|
|
- **Key Concerns**:
|
|
- Indoor air quality
|
|
- Off-gassing from materials
|
|
- Ventilation effectiveness
|
|
- Occupant health symptoms (headaches, irritation)
|
|
|
|
## Analysis Approach
|
|
|
|
The GPT service uses these standards to:
|
|
|
|
1. **Assess Current Conditions**: Compare measurements against optimal ranges
|
|
2. **Identify Issues**: Flag deviations with severity levels
|
|
3. **Provide Context**: Explain health/productivity impacts
|
|
4. **Recommend Actions**: Suggest specific interventions (HVAC, ventilation, etc.)
|
|
5. **Predict Trends**: Forecast potential issues based on patterns
|
|
|
|
## Multi-Metric Correlation
|
|
|
|
When analyzing multiple metrics together, the service looks for:
|
|
- **HVAC Performance**: Temperature + Humidity + CO2 trends
|
|
- **Ventilation Effectiveness**: CO2 + PM2.5 + VOC levels
|
|
- **Occupancy Impact**: CO2 rise + Temperature increase + Humidity changes
|
|
- **Seasonal Patterns**: Pressure + Temperature + Humidity correlations
|
|
|
|
## References
|
|
|
|
- ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy
|
|
- ASHRAE Standard 62.1: Ventilation for Acceptable Indoor Air Quality
|
|
- WHO Air Quality Guidelines
|
|
- ISO 7730: Ergonomics of the thermal environment
|
|
- EN 12464-1: Light and lighting of work places
|
|
- EPA Air Quality Index
|
|
- OSHA Occupational Noise Exposure Standards
|
|
|
|
## Usage in Prompts
|
|
|
|
The service automatically includes relevant standards in analysis prompts based on detected metrics. No manual configuration needed - just send your telemetry data!
|